Text & LLM data · Medical

Radiologist-reviewed radiology report data

AI-drafted radiology reports and imaging AI findings, reviewed by radiologists against the images themselves. They mark what the model missed, what it invented, left and right swapped, wrong comparisons with prior studies and impressions the findings don’t support, then write the corrected sentence. Images are de-identified and reports are synthetic, so no patient can be identified.

Reviewed by certified medical professionals

Specification

Studies
X-ray, CT and MRI of the chest, head, abdomen and spine, with prior studies for comparison
AI outputs
Draft reports from report-generation models and findings from detection models
Labels
Missed and invented findings, laterality errors, wrong comparison with priors, wrong measurements and the clinical significance of each error
Quality check
Reviewed by radiologists whose credentials Avenzoar has verified; significant errors confirmed by a second radiologist
Privacy
De-identified images and synthetic reports: no names, dates or other patient identifiers
Format
DICOM or PNG images; reports and error labels as JSON or CSV, each error tied to its sentence

Example of the data

What you see, and the file you get.

Preview
MissedSmall left pneumothoraxsignificant
Wrong sideNodule in the right lower lobeshould be left
Prior“Unchanged since prior”grew 4 → 7 mm
report_review.csvCSV · JSON · Excel
study_idmodalitydraft_sentenceerror_typeseveritycorrection
st_0001chest_xrayNo pneumothorax.missed_findingsignificantSmall left apical pneumothorax.
st_0002ct_chestA 7 mm nodule in the right lower lobe.lateralitysignificantA 7 mm nodule in the left lower lobe.
st_0002ct_chestUnchanged from the prior study.wrong_comparisonsignificantGrown from 4 mm to 7 mm since the prior study.
st_0003chest_xraySmall right pleural effusion.invented_findingminorNo pleural effusion.
st_0004mri_brainNo acute intracranial abnormality.
st_0005ct_abdomenImpression: acute appendicitis.unsupported_impressionsignificantImpression: normal appendix, no acute abnormality.

Sample rows. Also as JSON or Excel.

Contact us to get the dataset

Tell us what you need. We walk you through the data, its formats and how it is checked on a short call.

Contact us

What it is used for

  • Report generation models

    Train and fine-tune on drafts with radiologists’ corrections, sentence by sentence.

  • Hallucination and laterality checks

    Measure how often a model invents findings or swaps left and right.

  • Imaging AI validation

    Check detection models’ findings against radiologists’ reads before and after deployment.

  • Clinical benchmarks

    Compare models and releases on the same studies, with every error graded by clinical significance.

Questions

Is there real patient data in it?

No patient identifiers. Images are de-identified and reports are synthetic or AI-drafted, so there are no names, dates or record numbers in the data.

Who reviews the reports?

Radiologists whose credentials Avenzoar has verified. They read the images, mark every error in the draft and grade how much it matters clinically.

Can I see samples first?

Yes. Request samples with the form on this page and we will send them with the full specification.

Tell us what your model needs.

Request samples and the full specification. We reply within a couple of business days.

Request samples